Posted: 11 September 2020 at 16:03 |
How do I disable alarm function on Wurth TEV 0605 panel? Low water level alarm consistently on and not able to monitor other functions?
|
|
Breeze On
Lieutenant Joined: 21 February 2014 Location: Cambridge, MD Status: Offline Points: 47 |
Post Options
Thanks(0)
|
Looks like a 3sec press of the “enter” key...
6.2 SensorError It is a prerequisite for an error checking that the sensor is configured as “ENABLED” (see Figure 3 configuration). The signals of the sewage, water and diesel sensors and the battery voltage are compared to the configured min / max values. In the event of a lower deviation or overriding the main menu jumps to the sub-menu. In addition to the bar chart a blinking “!” also indicates the incorrect value. In this state the cursor key or cannot change to a different menu. Only the following is possible: . a) Short confirmation of the enter key to jump to the min / max setting menu. b) If the enter key is pressed for a duration of at least 3 seconds, the main menu is accessed. If several different sensor errors occur at the same time, these will also be automatically confirmed. Inaccurate values will then be indicated by a blinking „ ! “. Alarm terminable? |
|
George & Bev
Breeze On (415 #096) |
|
Matt
Captain Joined: 08 March 2014 Location: New York, USA Status: Offline Points: 217 |
Post Options
Thanks(0)
|
Not unless the issue is addressed. “Silencing” the alarm as described is the only option I’m aware of. If you have a faulty sensor then probably the only way is to disable “water” as a monitored item until resolved.
|
|
HANSE 445 #231 "ALBION"
|
|
Persephone
Sub Lieutenant Joined: 17 July 2017 Location: New England, US Status: Offline Points: 16 |
Post Options
Thanks(0)
|
The problem I ran into is that if the water in the tank is sloshing around silencing the alarm may only work for a few seconds before it re-alarms. I no longer use the Wurth panel for tank monitoring.
|
|
DHE @ 01945
Sub Lieutenant Joined: 11 September 2020 Location: Marblehead MA. Status: Offline Points: 3 |
Post Options
Thanks(0)
|
Thanks all!
Problem solved by disabling Freshwater Sensor from panel (press and hold up arrow and down arrow and enter functions simultaneously, then scroll to "Freshwater" and scroll down to DISABLE and enter... will enable angain after water hose repair and tank fill (which was underlying source of alarm display).
|
|